Bridgewater, MA – Beta Dyne, Inc. is proud to announce the release of the FW8S and FW8D DC/DC Converters. This is a 8 Watt Low-Noise with 2:1 input range which accepts 4.5 to 9VDC, 9 to 18VDC, or 18 to 36VDC AND 36 to 72VDC input with on/off control and generates all standard isolated outputs from 3.3 to 15VDC, or +/-5 to +/-15VDC. Custom output voltages and input voltage … [Read more...]
The Annual IEEE EMC Show – Why Dresden? Plus Proof of the Arbitrary Selection of Automotive Amplifier Harmonic Limits
Read other posts in the "Elephant in the Test Room" series here.It is looking good for using 3D software to diagnose the performance of the radiated emissions test fixture. Should get the go ahead any day now. Meantime, let’s explore this year’s hot topic. The Annual IEEE EMC Show - Why Dresden?It is no surprise that some USA residents in the EMC industry are wondering why the … [Read more...]
Determination of Practical Harmonic Levels
Well we are still waiting to see if borrowing 3D EM software is on the cards. I should know soon, one way or the other. I hope it happens, but for now let’s keep holding off on Elephant #3, ‘Fixing the Broken Automotive Test Fixture,’ In the meantime, we can continue the engineering approach on determining a practical level of harmonics in RF immunity for Elephant #2, … [Read more...]
Linearization of EMC Amplifiers Continued – Determining Practical Harmonic Levels
Read other posts in the "Elephant in the Test Room" series here.At the time of writing, I am waiting to see if borrowing 3D EM software is on the cards, so let’s postpone progress on Elephant #3 for the time being. I'm quite excited at the prospect of modeling the present automotive emissions test fixture, and equally important, modeling the proposed improvements. In the … [Read more...]
Linearization of EMC Amplifiers and Fixing the Broken Automotive Emissions Test Fixture
Read other posts in the "Elephant in the Test Room" series here.Linearization of EMC AmplifiersThis section of the posting got a little long-winded but it at least serves two purposes. It is a step closer to closing Elephant in the Test Room #2 ‘Disharmony in Harmonic Limits,’ and it also helps determine the linearization target on the TWT amplifier we are working with.The … [Read more...]
Elephant in the Test Room #3 – Fixing the Broken Automotive Emissions Test Fixture
Read other posts in the "Elephant in the Test Room" series here.Please note, regarding the fate of Elephant #2 – ‘Disharmony in Harmonic Limits’, it has now fallen under the umbrella of ‘Linearization of EMC Amplifiers’ and will be alluded to again during the part of the design exercise that determines practical harmonic levels. And so, with no further ado, onto a whole new … [Read more...]
Elephant in the Test Room #2 Continued and The Design Guide Article
Read other posts in the "Elephant in the Test Room" series here.Elephant #2 - Disharmony in Harmonic LimitsThe Room: RF immunity testingThe Elephant: The curbing of the contribution made by harmonics to a calibrated test-field varies wildly from standard to standard, and within standardsThe Culprit: Harmonic limits that are seemingly not well thought through, and / or are open … [Read more...]
Training the Intern and Elephant in the Test Room #2 Continued
Read other posts in the "Elephant in the Test Room" series here.Elephant #2 - Disharmony in Harmonic LimitsThe Room: RF immunity testingThe Elephant: The curbing of the contribution made by harmonics to a calibrated test-field varies wildly from standard to standard, and within standardsThe Culprit: Harmonic limits that are seemingly not well thought through, and / or are open … [Read more...]
The Linearization of EMC Amplifiers Continued & Introduction to Elephant in the Test Room #2
Read other posts in the "Elephant in the Test Room" series here.As promised in the last post, here is the start of the next elephant! Elephant #2 - Disharmony in Harmonic LimitsThe Room: RF immunity testingThe Elephant: The curbing of the contribution made by harmonics to a calibrated test-field varies wildly from standard to standard, and within standardsThe Culprit: Harmonic … [Read more...]
Elephant in the Test Room #1 Continued – Linearization of EMC Amplifiers
Read other posts in the "Elephant in the Test Room" series here.Recap On this ThreadThe room: MIL-STD RF immunity testing – 1-18GHz 200v/mThe elephant: everyone in the room is aware that a significant fraction of the ‘calibrated’ 200v/m test field is actually created at the wrong test frequency.The culprit: notoriously high ‘start of band’ harmonics produced by all octave band … [Read more...]