The International Electrotechnical Commission (IEC) has published IEC 60601-1-2:2014, "Medical Electrical Equipment - Part 1-2: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Electromagnetic Disturbances - Requirements and Tests." The new standard is available in the IEC's webstore here. "IEC 60601-1-2:2014 applies to the basic safety … [Read more...]
Standards
IEC 62761:2014: Guidelines for the Measurement Method of Nonlinearity for Surface Acoustic Wave (SAW) and Bulk Acoustic Wave (BAW) Devices in Radio Frequency (RF)
From the International Electrotechnical Commission webstore: "IEC 62761:2014-02(en-fr) gives the measurement method for nonlinear signals generated in the radio frequency (RF) surface acoustic wave (SAW) and bulk acoustic wave (BAW) devices such as filters and duplexers, which are used in telecommunications, measuring equipment, radar systems and consumer products. It includes … [Read more...]
CISPR 16-4-2:2011+A1:2014: Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods – Part 4-2: Uncertainties, Statistics and Limit Modeling – Measurement Instrumentation Uncertainty
From the International Electrotechnical Commission webstore: "CISPR 16-4-2:2011+A1:2014 is a basic EMC publication. It specifies the method of applying Measurement Instrumentation Uncertainty (MIU) when determining compliance with CISPR disturbance limits. The material is also relevant to any EMC test when interpretation of the results and conclusions reached will be impacted … [Read more...]
IEC 60974-10:2014: Arc Welding Equipment – Part 10: Electromagnetic Compatibility (EMC) Requirements
From the International Electrotechnical Commission webstore: "IEC 60974-10:2014 specifies: a) applicable standards and test methods for radio-frequency (RF) emissions; b) applicable standards and test methods for harmonic current emission, voltage fluctuations and flicker; c) immunity requirements and test methods for continuous and transient, conducted and radiated … [Read more...]
IEC/TR 61869-102:2014(E): Instrument Transformers – Part 102: Ferroresonance Oscillations in Substations with Inductive Voltage Transformers
From the International Electrotechnical Commission webstore: "IEC/TR 61869-102:2014(E) provides technical information for understanding the undesirable phenomenon of ferroresonance oscillations in medium voltage and high voltage networks in connection with inductive voltage transformers. Ferroresonance can cause considerable damage to voltage transformers and other equipment. … [Read more...]
IEC TS 62153-4-1:2014(E): Metallic Communication Cable Test Methods – Part 4-1: EMC – Introduction to Electromagnetic Screening Measurements
From the International Electrotechnical Commission webstore: "IEC TS 62153-4-1:2014(E) deals with screening measurements. Screening (or shielding) is one basic way of achieving electromagnetic compatibility (EMC). However, a confusingly large number of methods and concepts are available to test for the screening quality of cables and related components, and for defining their … [Read more...]
IEC 60794-1-20 ed1.0: Optical Fiber Cales – Part 1-20: Generic Specification – Basic Optical Cable Test Procedures – General and Definitions
From the International Electrotechnical Commission webstore: "IEC 60794-1-20:2014 applies to optical fiber cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibers and electrical conductors. The object of this standard is to define test procedures to be used in establishing uniform … [Read more...]
EN 12016:2013: EMC – Product Family Standard for Lifts, Escalators and Moving Walks – Immunity
From the European Committee for Standardization: "This European Standard specifies the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment. These levels represent essential EMC … [Read more...]
IEC 62586-2:2013: Power Quality Measurement in Power Supply Systems – Part 2: Functional Tests and Uncertainty Requirements
From the International Electrotechnical Commission webstore: "IEC 62586-2:2013 specifies functional tests and uncertainty requirements for instruments whose functions include measuring, recording, and possibly monitoring power quality parameters in power supply systems, and whose measuring methods (class A or class S) are defined in IEC 61000-4-30. This standard applies to … [Read more...]
IEC 61786-1:2013: Measurement of DC Magnetic, AC Magnetic and AC Electric Fields from 1 Hz to 100 kHz with Regard to Exposure of Human Beings – Part 1: Requirements for Measuring Instruments
From the International Electrotechnical Commission webstore: "IEC 61786-1:2013 provides guidance for measuring instruments used to measure the field strength of quasi-static magnetic and electric fields that have a frequency content in the range 1 Hz to 100 kHz and with DC magnetic fields to evaluate the exposure levels of the human body to these fields. Sources of fields … [Read more...]